A Comparison Between the Use of an Infrared Contact Mat and an IMU During Kinematic Analysis of Horizontal Jumps
| aut.relation.endpage | 14 | |
| aut.relation.issue | 1 | |
| aut.relation.journal | Biomechanics (Switzerland) | |
| aut.relation.startpage | 14 | |
| aut.relation.volume | 5 | |
| dc.contributor.author | Johansen, B | |
| dc.contributor.author | Neville, J | |
| dc.contributor.author | van den Tillaar, R | |
| dc.date.accessioned | 2025-05-16T00:07:02Z | |
| dc.date.available | 2025-05-16T00:07:02Z | |
| dc.date.issued | 2025-03-02 | |
| dc.description.abstract | Background/Objectives: This study compared step-by-step kinematic measurements from an infrared contact mat (IR-mat) and an inertial measurement unit (IMU) system during bounding and single leg jumping for speed, while also evaluating the validity of algorithms originally developed for sprinting and running when applied to horizontal jumps. The aim was to investigate differences in contact times between the systems. Methods: Nineteen female football players (15 ± 0.5 years, 61.0 ± 5.9 kg, 1.70 ± 0.06 m) performed attempts in both jumps over 20 m with maximum speed, of which the first eight steps were analysed. Results: Significant differences were found between the systems, with the IR-mat recording longer contact times than the IMU. The IR-mat began and ended its measurements slightly earlier and later, respectively, compared to the IMU system, likely due to the IMU’s algorithm, which was developed for sprinting with forefoot contact, while more midfoot and heel landing is used during jumps. Conclusions: Both systems provide reliable measurements; however, the IR mat consistently records slightly longer contact times for horizontal jumps. While the IMU is dependable, it exhibits a consistent bias compared to the IR mat. For bounding, the IR mat begins recording 0.018 s earlier at touch down and stops 0.021 s later. For single leg jumps, it starts 0.024 s earlier and ends 0.021 s later, resulting in contact times that are, on average, 0.039–0.045 s longer. These findings provide valuable insights for coaches and researchers in selecting appropriate measurement tools, highlighting the systematic differences between IR mats and IMUs in horizontal jump analysis. | |
| dc.identifier.citation | Biomechanics (Switzerland), ISSN: 2673-7078 (Print); 2673-7078 (Online), MDPI AG, 5(1), 14-14. doi: 10.3390/biomechanics5010014 | |
| dc.identifier.doi | 10.3390/biomechanics5010014 | |
| dc.identifier.issn | 2673-7078 | |
| dc.identifier.issn | 2673-7078 | |
| dc.identifier.uri | http://hdl.handle.net/10292/19211 | |
| dc.language | en | |
| dc.publisher | MDPI AG | |
| dc.relation.uri | https://www.mdpi.com/2673-7078/5/1/14 | |
| dc.rights | All articles published by MDPI are made immediately available worldwide under an open access license. No special permission is required to reuse all or part of the article published by MDPI, including figures and tables. For articles published under an open access Creative Common CC BY license, any part of the article may be reused without permission provided that the original article is clearly cited. For more information, please refer to https://www.mdpi.com/openaccess. | |
| dc.rights.accessrights | OpenAccess | |
| dc.subject | 42 Health Sciences | |
| dc.subject | 4207 Sports Science and Exercise | |
| dc.subject | Bioengineering | |
| dc.subject | step kinematics | |
| dc.subject | measurement accuracy | |
| dc.subject | bounding | |
| dc.subject | single leg jump | |
| dc.title | A Comparison Between the Use of an Infrared Contact Mat and an IMU During Kinematic Analysis of Horizontal Jumps | |
| dc.type | Journal Article | |
| pubs.elements-id | 600434 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Comparison Between the Use of an Infrared Contact Mat.pdf
- Size:
- 1.02 MB
- Format:
- Adobe Portable Document Format
- Description:
- Journal article