<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
Repository logo

Can Lateral Cyclic Reactive Jump Ability Be Reliably Measured Using an Inertial Measurement Unit?

Loading...
Thumbnail Image

Files

Size: 2.42 MB, File format: Adobe PDF

Authors

Michalak, Margaret M

Ryan, Chloe M

Ehlert, Alex

Lian, Yuxiao

Slocum, Christopher

Bennett, Leslie

Villarreal, Hailey

Cronin, John

Supervisor

Degree name

Journal Title

Journal ISSN

Volume Title

Publisher

MDPI AG

Abstract

Jump testing is widely used to assess lower-limb power, force absorption, and stretch-shortening cycle (SSC) function; however, lateral cyclic tests remain underexplored despite their relevance to change-of-direction performance. This study determined the intra- and inter-session reliability of a novel cyclic lateral leg power test using an inertial measurement unit (IMU). Seventeen female athletes completed three identical testing sessions separated by seven days. Participants performed 10 consecutive lateral bounds at distances of 1.0×, 1.25×, and 1.5× leg length on each limb. A foot-mounted inertial measurement unit (IMU) (Output Sports Ltd., Dublin, Ireland) quantified contact time (CT) and air time (AT), with the five shortest values for each variable analyzed. Reliability was assessed using percent change in the mean, coefficients of variation (CV), and intraclass correlation coefficients (ICC). Between-session changes were small (−7.9% to 6.6%), with no significant session effects for CT or AT. CVs ranged from 9.2% to 21.8%, with only CT at 1.0× leg length between Sessions 1 and 2 below 10%. ICCs ranged from 0.12 to 0.76, indicating poor-to-good relative reliability. Overall, the IMU-instrumented lateral cyclic test demonstrated largely unacceptable reliability, particularly at greater jump distances, indicating that further protocol refinement is required before implementation in clinical or performance settings.

Description

Keywords

40 Engineering, 46 Information and Computing Sciences, 4008 Electrical Engineering, 4009 Electronics, Sensors and Digital Hardware, 4606 Distributed Computing and Systems Software, Clinical Research, 0301 Analytical Chemistry, 0805 Distributed Computing, 0906 Electrical and Electronic Engineering, 4009 Electronics, sensors and digital hardware, change of direction, stretch-shortening cycle, contact time, air time, female athletes, wearable technology, sports performance

Source

Sensors, ISSN: 1424-8220 (Print); 1424-8220 (Online), MDPI AG, 26(20), 6532-6532. doi: 10.3390/s26206532

Rights statement

© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article.

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Creative Commons Attribution (CC BY) license