Seismic Assessment of a Full-scale Perimeter-fixed Ceiling With Hook-and-loop-secured Lay-in Tiles Using Shake Table Tests

aut.relation.endpage25
aut.relation.issueahead-of-print
aut.relation.journalJournal of Earthquake Engineering
aut.relation.startpage1
aut.relation.volumeahead-of-print
dc.contributor.authorTiwari, A
dc.contributor.authorBhatta, J
dc.contributor.authorDhakal, RP
dc.contributor.authorSullivan, TJ
dc.contributor.authorShrestha, RK
dc.contributor.authorRashid, M
dc.contributor.authorYan, Z
dc.contributor.authorMacRae, GA
dc.contributor.authorYu, J
dc.contributor.authorXiang, P
dc.contributor.authorZhang, Y
dc.contributor.authorJia, L
dc.contributor.authorRamhormozian, S
dc.contributor.authorClifton, GC
dc.contributor.authorQuenneville, P
dc.contributor.authorRodgers, G
dc.contributor.authorZhao, X
dc.date.accessioned2026-09-22T02:11:59Z
dc.date.issued2026-09-09
dc.description.abstractGrid-and-tile ceiling systems are widely installed in commercial buildings but have frequently experienced damage in past earthquakes, resulting in safety risks, costly repairs, and operational interruptions. The present study examines the seismic performance of a perimeter-fixed ceiling incorporating hook-and-loop-secured lay-in tiles, an improved version of a conventional perimeter-fixed ceiling where tiles are not mechanically fastened to the Tees. Hook-and-loop tape at the tile–Tee interface offers an effective means to prevent tile dislodgement and collapse during shaking. The ceiling was installed over half of the third-floor span of a full-scale, three-storey steel-framed building and subjected to unidirectional and bidirectional excitation as part of the non-structural elements testing program of the New Zealand–China collaborative RObust BUilding SysTem (ROBUST) project. The ceiling was subjected to peak floor accelerations of 1.21 g (vector resultant). The observed median fundamental modal periods and median damping ratios lay in the ranges 0.07–0.08 s and 0.93–2.07%, respectively. The median horizontal acceleration amplification factor was 1.07, and the maximum peak component ceiling acceleration in the vertical direction reached 0.38 g. The maximum displacement recorded in the ceiling was 1.89 mm. Lay-in tiles did not experience any pounding with sprinkler heads, and no ceiling components sustained any damage. The hook-and-loop-secured perimeter-fixed ceiling exhibited improved seismic performance compared with conventional perimeter-fixed ceilings. The use of hook-and-loop tape to mechanically connect lay-in tiles to the Tees was shown to be simple and practical for both new installations and retrofit applications. Overall, the system can be regarded as a low-damage, seismically resilient ceiling solution.
dc.identifier.citationJournal of Earthquake Engineering, ISSN: 1363-2469 (Print); 1559-808X (Online), Informa UK Limited, ahead-of-print(ahead-of-print), 1-25. doi: 10.1080/13632469.2026.2710661
dc.identifier.doi10.1080/13632469.2026.2710661
dc.identifier.issn1363-2469
dc.identifier.issn1559-808X
dc.identifier.urihttp://hdl.handle.net/10292/22024
dc.languageen
dc.publisherInforma UK Limited
dc.relation.urihttps://www.tandfonline.com/doi/full/10.1080/13632469.2026.2710661
dc.rights© 2026 The Author(s). Published with license by Taylor & Francis Group, LLC. This is an Open Access article.
dc.rights.accessrightsOpenAccess
dc.rights.licenseCreative Commons Attribution-NonCommercial-NoDerivatives License
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject4005 Civil Engineering
dc.subject40 Engineering
dc.subject0905 Civil Engineering
dc.subjectStrategic, Defence & Security Studies
dc.subject4005 Civil engineering
dc.subjectPerimeter-fixed ceiling
dc.subjectlay-in tiles
dc.subjecthook-and-loop tape
dc.subjectshake table
dc.subjectlow-damage ceiling
dc.subjectdynamic characterization
dc.titleSeismic Assessment of a Full-scale Perimeter-fixed Ceiling With Hook-and-loop-secured Lay-in Tiles Using Shake Table Tests
dc.typeJournal Article
pubs.elements-id775004

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Seismic Assessment of a Full-Scale Perimeter-Fixed Ceiling with Hook-And-Loop-Secured Lay-In Tiles Using Shake Table Tests.pdf
Size:
8.95 MB
Format:
Adobe Portable Document Format
Description:
Journal article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.37 KB
Format:
Plain Text
Description: