Repository logo

Power Quality and Performance Assessment of Grid-connected Photovoltaic Distributed Generation With Compliance to Stipulated Grid Integration Requirements

aut.relation.endpage10
aut.relation.issue7
aut.relation.journalEuropean Journal of Engineering and Technology Research
aut.relation.startpage1
aut.relation.volume6
dc.contributor.authorNkado, Fredrick
dc.contributor.authorNkado, Franklin
dc.date.accessioned2026-08-20T01:36:42Z
dc.date.issued2021-11-04
dc.description.abstract<jats:p>Recently, the demand for electrical energy has increased more than energy production due to the growing population and industrialization. Therefore, the distributed generators integration (DGs) into the distribution system has been widely adopted. This work examines the effect of photovoltaic-based distributed generator (PV-DG) integration on power quality effect of a radial distribution system. Firstly, the capacity and optimum placement of the PV-DG units in the distribution network are determined by employing the particle swarm optimization (PSO) algorithm. Then, the impact of PV-DG integration on voltage harmonic distortion is analyzed by performing harmonic load flow analysis. Also, the P-V curve method is used to evaluate the effects of higher PV-DG penetration levels on loading margin and voltage magnitude. The simulation results show that as the PV-DG units’ penetration level increases, a greater level of harmonic distortion is injected, implying that the PV-DG units should only be integrated up to the network’s maximum capacity. Therefore, high harmonic distortion is produced when the PV-DG units are penetrated beyond this maximum penetration level, which has a negative impact on the system’s performance. The total voltage harmonic distortion is 4.17 % and 4.24 % at PCC1 and PCC2 at the highest penetration level, allowing the acceptable harmonic distortion limit. Also, grid-connected PV-DG units improve loading margin and voltage magnitude, according to the P-V curve results. The standard IEEE-33 bus distribution system is modelled in ETAP software and is used as a test system for this study.</jats:p>
dc.identifier.citationEuropean Journal of Engineering and Technology Research, ISSN: 2736-576X (Print); 2736-576X (Online), European Open Science Publishing, 6(7), 1-10. doi: 10.24018/ejeng.2021.6.7.2628
dc.identifier.doi10.24018/ejeng.2021.6.7.2628
dc.identifier.issn2736-576X
dc.identifier.issn2736-576X
dc.identifier.urihttp://hdl.handle.net/10292/21810
dc.publisherEuropean Open Science Publishing
dc.relation.urihttps://eu-opensci.org/index.php/ejeng/article/view/62628
dc.rightsCreative Commons Attribution ShareAlike CC BY-SA
dc.rights.accessrightsOpenAccess
dc.rights.urihttps://creativecommons.org/licenses/by-sa/4.0/
dc.subject40 Engineering
dc.subject4008 Electrical Engineering
dc.subject4009 Electronics, Sensors and Digital Hardware
dc.subject7 Affordable and Clean Energy
dc.subjectDistribution system
dc.subjectETAP
dc.subjectPhotovoltaic-Distribution Generation (PV-DG)
dc.subjectP-V curve
dc.subjectParticle swarm optimization (PSO)
dc.subjectPower quality
dc.titlePower Quality and Performance Assessment of Grid-connected Photovoltaic Distributed Generation With Compliance to Stipulated Grid Integration Requirements
dc.typeJournal Article
pubs.elements-id600208

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
editor_in_chief,+ejers_2628.pdf
Size:
918.57 KB
Format:
Adobe Portable Document Format
Description:
Journal article

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.37 KB
Format:
Plain Text
Description: