Stirling-cycle heat-pumps and refrigerators – a realistic alternative?
aut.conference.type | Paper Published in Proceedings | |
aut.researcher | Gschwendtner, Michael | |
dc.contributor.author | Haywood, D | |
dc.contributor.author | Raine, JK | |
dc.contributor.author | Gschwendtner, MA | |
dc.date.accessioned | 2012-12-18T01:58:34Z | |
dc.date.available | 2012-12-18T01:58:34Z | |
dc.date.copyright | 2002 | |
dc.date.issued | 2002 | |
dc.description.abstract | Concerns about the environmental impact of refrigerants used in vapour-compression heatpumps and refrigerators, have prompted the Stirling-Cycle Research Group at the University of Canterbury to investigate the feasibility of low-cost Stirling-cycle machines that use air as the refrigerant. Such machines theoretically have the highest efficiency possible for any practical thermodynamic system, and thus provide a tempting alternative to traditional vapourcompression technology. This paper outlines the working principles of Stirling-cycle heat-pumps and refrigerators, and describes some of the work performed at Canterbury University. Some of the heat-pump development programme results are also presented, and briefly discussed. | |
dc.identifier.citation | Institute of Refrigeration, Heating & Air Conditioning Engineers (IHRACE) 2002 Conference, Christchurch, New Zealand. | |
dc.identifier.uri | https://hdl.handle.net/10292/4942 | |
dc.publisher | Institute of Refrigeration, Heating & Air Conditioning Engineers (IRHACE) | |
dc.rights | Auckland University of Technology (AUT) encourages public access to AUT information and supports the legal use of copyright material in accordance with the Copyright Act 1994 (the Act) and the Privacy Act 1993. Unless otherwise stated, copyright material contained on this site may be in the intellectual property of AUT, a member of staff or third parties. Any commercial exploitation of this material is expressly prohibited without the written permission of the owner. | |
dc.rights.accessrights | OpenAccess | |
dc.title | Stirling-cycle heat-pumps and refrigerators – a realistic alternative? | |
dc.type | Conference Contribution | |
pubs.elements-id | 132155 | |
pubs.organisational-data | /AUT | |
pubs.organisational-data | /AUT/Design & Creative Technologies | |
pubs.organisational-data | /AUT/Design & Creative Technologies/School of Engineering |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Stirling-Cycle Heat-Pumps and Refrigerators – a Realistic Alternative_IHRACE 2002.pdf
- Size:
- 426.4 KB
- Format:
- Adobe Portable Document Format
- Description:
License bundle
1 - 1 of 1