<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
Repository logo

Ultrasound Evaluation of the Abductor Hallucis Muscle in Youth: A Reliability Study

Loading...
Thumbnail Image

Files

Size: 905.97 KB, File format: Adobe PDF

Authors

Squibb, Maisie

Monks, Dean

Nulty, Christopher D

Sheerin, Kelly

Francis, Peter

Supervisor

Degree name

Journal Title

Journal ISSN

Volume Title

Publisher

Wiley

Abstract

Introduction Abductor hallucis (AbdH) is an intrinsic foot muscle and a stabiliser of the medial longitudinal arch. Its cross-sectional area (CSA) is routinely measured by ultrasound (US) and is highly relevant to foot muscle development. However, the reliability of portable US for measuring AbdH CSA in healthy youth is unknown. Therefore, the aim of this study was to examine the inter-device association, inter-rater reliability and inter-session reliability of portable US for measuring AbdH CSA in youth.

Methods Twenty-seven youths (11–17 years; 14 male, 13 female) participated, with inter-device association and inter-rater reliability assessed in a subgroup of n = 12 and intra-rater inter-session reliability in n = 15. AbdH CSA images were captured on two occasions one week apart using a 5–15 MHz handheld US unit (L15HD, Clarius), while a single image was captured using a cart-based US device (3–16 MHz; HS40, Samsung) for inter-device comparison. Reliability was assessed using intraclass correlation coefficients (two-way mixed-effects, absolute agreement). Inter-device comparison was evaluated using Pearson's correlation, linear regression and paired-sample t-test for systematic differences, and measurement error was quantified using the standard error of measurement (SEM).

Results Portable and cart-based US measurements of AbdH CSA showed a strong positive correlation (r = 0.938, p < 0.001), although mean values were 0.19 cm2 higher with the cart-based device (p = 0.002). Inter-rater reliability was excellent (ICC(3, 3) = 0.934, 95% CI: 0.786–0.980) with no significant difference between assessors (p = 0.823), minimal bias (−0.01 cm2), and a SEM of 0.039 cm2. Inter-session reliability was also excellent (ICC(3, 3) = 0.969, 95% CI: 0.911–0.989) with no significant difference between sessions (p = 0.788), minimal bias (0.007 cm2) and a SEM of 0.013 cm2.

Conclusion A portable US device demonstrated excellent inter-rater and inter-session reliability for measuring AbdH CSA in youth and was strongly associated with cart-based US measurements.

Description

Keywords

1103 Clinical Sciences, 1104 Complementary and Alternative Medicine, 1106 Human Movement and Sports Sciences, 3202 Clinical sciences, 4201 Allied health and rehabilitation science, 4207 Sports science and exercise, anatomy, children, foot structures, medial longitudinal arch, paediatrics

Source

Journal of Foot and Ankle Research, ISSN: 1757-1146 (Print); 1757-1146 (Online), Wiley, 19(4). doi: 10.1002/jfa2.70230

Rights statement

© 2026 The Author(s). Journal of Foot and Ankle Research published by John Wiley & Sons Australia, Ltd on behalf of Australian Podiatry Association and The Royal College of Podiatry. This is an open access article.

Endorsement

Review

Supplemented By

Referenced By

Creative Commons license

Except where otherwise noted, this item's license is described as Creative Commons Attribution License