Screening for Atrial Fibrillation during Automatic Blood Pressure Measurements

aut.relation.journalIEEE Journal of Translational Engineering in Health and Medicine
aut.relation.startpage4400307
aut.relation.volume6
dc.contributor.authorLowe, Andrew
dc.contributor.authorOh, Timothy
dc.contributor.authorStewart, Ralph
dc.date.accessioned2026-11-02T19:54:39Z
dc.date.issued2018-10-09
dc.description.abstractAtrial fibrillation (Afib) contributes significantly to overall cardiovascular risk. Widespread screening for Afib in primary care is sometimes performed by palpation, but suffers from low accuracy and is dependent on clinician experience. Algorithms implemented on oscillometric blood pressure devices can detect Afib with high sensitivity and specificity, but information on factors affecting accuracy is scant. Concurrent diagnostic electrocardiogram (ECG) and oscillometry were measured in participants in ECG clinics at two sites. Root mean squared successive difference (RMSSD) and irregularity index (Irrx) were calculated from oscillometric data and used to train logistic regression classifiers. Monte Carlo cross validation with 20 splits was performed to estimate confidence intervals for mean sensitivity and specificity, with various weightings, in the absence or presence of ectopics, and with or without repeated measurements. 707 measurements, including 168 Afib, were collected from 569 participants with mean (standard deviation) age of 63 (16) years. Sensitivity/specificity of RMSSD and Irrx were 0.982/0.908 and 0.986/0.960 respectively when ectopics were included. Excluding ectopics from the data improved specificity by up to 5%. Nevertheless, based on this performance and after accounting for prevalence of Afib in the population aged over 60 years, and estimated costs of healthcare, oscillometric screening for Afib in this age group could return a positive net health-economic benefit.
dc.identifier.citationIEEE Journal of Translational Engineering in Health and Medicine, ISSN: 2168-2372 (Print); 2168-2372 (Online), Institute of Electrical and Electronics Engineers (IEEE), 6, 4400307-. doi: 10.1109/JTEHM.2018.2869609
dc.identifier.doi10.1109/JTEHM.2018.2869609
dc.identifier.issn2168-2372
dc.identifier.issn2168-2372
dc.identifier.urihttp://hdl.handle.net/10292/22290
dc.languageeng
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.relation.urihttps://ieeexplore.ieee.org/document/8486979
dc.rights© 2018 IEEE. Open access.
dc.rights.accessrightsOpenAccess
dc.subjectAtrial fibrillation
dc.subjectbiomedical signal processing
dc.subjectmedical conditions
dc.subjectmedical tests
dc.subjectoscillometric blood pressure
dc.subject4203 Health Services and Systems
dc.subject40 Engineering
dc.subject42 Health Sciences
dc.subject4003 Biomedical Engineering
dc.subjectHeart Disease
dc.subjectHealth Services
dc.subjectCardiovascular
dc.subjectClinical Research
dc.subject4.2 Evaluation of markers and technologies
dc.subject3 Good Health and Well Being
dc.subject4003 Biomedical engineering
dc.subject4203 Health services and systems
dc.titleScreening for Atrial Fibrillation during Automatic Blood Pressure Measurements
dc.typeJournal Article