Reliability of the TekScan MatScan(R) system for the measurement of postural stability in older people with rheumatoid arthritis

aut.researcherRome, Keith
dc.contributor.authorRome, K
dc.date.accessioned2012-10-01T01:19:02Z
dc.date.available2012-10-01T01:19:02Z
dc.date.copyright2012
dc.date.issued2012
dc.description.abstractBackground: Postural stability can be measured in clinical and research settings using portable plantar pressure systems. People with rheumatoid arthritis (RA) have decreased postural stability compared to non-RA populations and impaired postural stability is associated with falls in people with RA. The purpose of this study was therefore to investigate the reliability of the TekScan MatScanW system in assessing postural stability in people with RA. Methods: Twenty three participants with RA, mean (SD) age 69.74 (10.1) years, were assessed in barefoot double limb quiet standing, with eyes open and eyes closed, for antero-posterior and medio-lateral postural sway values. Three repetitions, at a sampling frequency of 40 Hz, were recorded for each test condition to obtain a mean value. Measurements were repeated one hour later. Intraclass correlation coefficients (ICC) with 95% confidence intervals (CI) were calculated to determine between-session reliability. Measurement error was assessed through the calculation of the standard error of the measurement (SEM) and the smallest real difference (SRD). Results: The system displayed good to excellent reliability for antero-posterior and medio-lateral sway, with eyes open and closed, as indicated by ICC values ranging from 0.84 to 0.92. Measurement error, as evidenced by the SEM, ranged from 1.27 to 2.35 mm. The degree of change required to exceed the expected trial to trial variability was relatively high, compared to mean values, with SRD ranging from 3.08 to 5.71 mm. Conclusions: The portability and ease of use of the TekScan MatScanW makes it a useful tool for the measurement of postural stability in clinical and research settings. The TekScan MatScanW system can reliably measure double limb quiet standing in older people, aged 60 to 80 years, with RA.
dc.identifier.citationJournal of Foot and Ankle Research 2012, 5:21
dc.identifier.doi10.1186/1757-1146-5-21
dc.identifier.urihttps://hdl.handle.net/10292/4618
dc.publisherBioMed Central Ltd.
dc.rights© 2012 Brenton-Rule et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.rights.accessrightsOpenAccess
dc.subjectPostural sway
dc.subjectBalance
dc.subjectFalls
dc.subjectRheumatoid arthritis
dc.subjectPressure system
dc.titleReliability of the TekScan MatScan(R) system for the measurement of postural stability in older people with rheumatoid arthritis
dc.typeJournal Article
pubs.organisational-data/AUT
pubs.organisational-data/AUT/Health & Environmental Science
pubs.organisational-data/AUT/PBRF Researchers
pubs.organisational-data/AUT/PBRF Researchers/Health & Environmental Sciences PBRF Researchers
pubs.organisational-data/AUT/PBRF Researchers/Health & Environmental Sciences PBRF Researchers/HES R & O Podiatry
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Brenton Rule 2012.pdf
Size:
258.44 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
licence.htm
Size:
29.98 KB
Format:
Unknown data format
Description: