Test-retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke

aut.relation.endpage887
aut.relation.issue10-11
aut.relation.startpage871
aut.relation.volume22
dc.contributor.authorMudge, S
dc.contributor.authorStott, NS
dc.date.accessioned2013-05-21T03:14:57Z
dc.date.available2013-05-21T03:14:57Z
dc.date.copyright2008
dc.date.issued2008
dc.description.abstractObjective: To examine the test—retest reliability of the StepWatch Activity Monitor outputs over two periods, a week apart, in participants with stroke. Design: Test—retest reliability study over monitoring periods of one, two and three days. Setting: Participant's usual environment. Participants: Forty participants more than six months post stroke. Main measures: StepWatch outputs: total step count, number of steps at high medium and low stepping rates, sustained activity indices, peak activity index. Results: The intraclass correlation coefficients were high for all StepWatch outputs and all monitoring periods but were highest for the three-day monitoring period (0.930—0.989) and lowest for the one-day monitoring period (0.830—0.950). The coefficient of variation ranged from 6.7% to 48.7% over the monitoring periods, with higher variation shown for shorter monitoring periods. The most reliable four outputs had 95% limits of agreement between three-day periods that were less than 40%. These were total step count (±37.8%), highest step rate in 1 minute (±23.0%), highest step rate in 5 minutes (±38.6%) and peak activity index (±29.8%). The highest step rate in 1 minute was the only StepWatch output that had 95% limits of agreement less than 40% for the two-day (±31.2%) and one-day (±36.7%) monitoring periods. Conclusions: Total step count, highest step rate in 1 minute, highest step rate in 5 minutes and peak activity index have good test—retest reliability over a three-day monitoring period, with lower reliability shown by the other StepWatch outputs. In general, monitoring over one or two days is less reliable.
dc.identifier.citationClinical Rehabilitation, vol.22(10-11), pp.871 - 887
dc.identifier.doi10.1177/0269215508092822
dc.identifier.roid11998en_NZ
dc.identifier.urihttps://hdl.handle.net/10292/5353
dc.publisherSage
dc.rightsAuthors retain the right to place his/her pre-publication version of the work on a personal website or institutional repository. This article may not exactly replicate the final version published. It is not the copy of record. The final, definitive version of this paper has been published by SAGE Publications Ltd. All rights reserved. © 2008. (please see Citation and Publisher’s Version).
dc.rights.accessrightsOpenAccess
dc.subjectCerebrovascular accident
dc.subjectGait
dc.subjectRehabilitation
dc.subjectActivity
dc.titleTest-retest reliability of the StepWatch Activity Monitor outputs in individuals with chronic stroke
dc.typeJournal Article
pubs.elements-id14141
pubs.organisational-data/AUT
pubs.organisational-data/AUT/Health & Environmental Science
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Test-retest reliability.pdf
Size:
208.11 KB
Format:
Adobe Portable Document Format
Description:
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
licence.htm
Size:
30.34 KB
Format:
Unknown data format
Description: