Simulation of Impedance Measurements at Human Forearm Within 1 KHz to 2 MHz

aut.relation.articlenumber1en_NZ
aut.relation.endpage20
aut.relation.journalJournal of Electrical Bioimpedanceen_NZ
aut.relation.startpage20
aut.relation.volume7en_NZ
aut.researcherLowe, Andrew
dc.contributor.authorAnand, Gen_NZ
dc.contributor.authorLowe, Aen_NZ
dc.contributor.authorAl-Jumaily, AMen_NZ
dc.date.accessioned2017-07-30T22:08:34Z
dc.date.available2017-07-30T22:08:34Z
dc.date.copyright2016-05en_NZ
dc.date.issued2016-05en_NZ
dc.description.abstractThis work presents a simulation analysis of the bioimpedance measurements at human forearm. The Ansys® High Frequency Structure Simulator (HFSS) has been used to analyze the electrical response of a section of human forearm with three domains of di-electric behavior- fat, muscle and artery (blood). The impedance values were calculated as the ratio of the output voltage at the electrodes to the applied known current (1mA). A model was developed and was simulated for impedance values obtained within a frequency range of 1 kHz to 2MHz. The measurements were done at three instances of radial artery diameter. The maximum resistance and reactance values were calculated as 445Ω and 178.5Ω, 356Ω and 138Ω, and 368Ω and 144.3Ω for diameters 2.3mm, 2.35mm, and 2.4mm respectively. The set of impedance values obtained followed Cole-plot trend. The results obtained were found to be in excellent agreement with the Cole theory. The set of values obtained at three different diameters reflected the effect of blood flow on impedance values.
dc.identifier.citationJournal of Electrical Bioimpedance, 7(1), 20-27.
dc.identifier.doi10.5617/jeb.2657en_NZ
dc.identifier.issn1891-5469en_NZ
dc.identifier.urihttps://hdl.handle.net/10292/10709
dc.publisherUniversity of Oslo Library
dc.relation.urihttps://www.journals.uio.no/index.php/bioimpedance/article/view/2657en_NZ
dc.rightsThis journal provides immediate open access to its content on the principle that making research freely available to the public supports a greater global exchange of knowledge.
dc.rights.accessrightsOpenAccessen_NZ
dc.subjectBioimpedance; β dispersion; Cole plot; Forearm
dc.titleSimulation of Impedance Measurements at Human Forearm Within 1 KHz to 2 MHzen_NZ
dc.typeJournal Article
pubs.elements-id205556
pubs.organisational-data/AUT
pubs.organisational-data/AUT/Design & Creative Technologies
pubs.organisational-data/AUT/Design & Creative Technologies/Engineering, Computer & Mathematical Sciences
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Simulation of impedance measurements.pdf
Size:
1.33 MB
Format:
Adobe Portable Document Format
Description:
Journal article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AUT Grant of Licence for Scholarly Commons Feb2017.pdf
Size:
239.25 KB
Format:
Adobe Portable Document Format
Description: