Repository logo
 

Advanced Technique for EEG and HRV Measurement Using Around-Ear Capacitive Electrodes

aut.relation.conference2024 IEEE 20th International Conference on Body Sensor Networks (BSN)
aut.relation.endpage4
aut.relation.startpage1
aut.relation.volume00
dc.contributor.authorShaikh, Usman Qamar
dc.contributor.authorKalra, Anubha Manju
dc.contributor.authorLowe, Andrew
dc.contributor.authorNiazi, Imran Khan
dc.date.accessioned2025-05-28T20:42:34Z
dc.date.available2025-05-28T20:42:34Z
dc.date.issued2024-12-11
dc.description.abstractLong-term electroencephalogram (EEG) monitoring requires devices that are unobtrusive, comfortable, and user-friendly. Capacitive electrodes, unlike gel or dry electrodes, do not require direct galvanic skin contact, making them ideal for extended use. This paper investigates the efficacy of capacitive electrodes for recording four biopotential channels from around-ear areas. A printed circuit board was developed and assessed through an alpha-block experiment. The posterior-ear capacitive EEG achieved a statistically significant power gain (APSD) of 2.77 dB in the alpha band and 5.84 dB at 10 Hz. Additionally, a mean absolute error (MAE) of 8.9 milliseconds was observed between heart rate variability (HRV) measurements from a capacitive superior-ear electrode and shoulder ECG. These results indicate that around-ear capacitive electrodes are suitable for multimodal biopotential applications, offering a promising solution for long-term EEG monitoring.
dc.identifier.doi10.1109/bsn63547.2024.10780484
dc.identifier.isbn9798331530143
dc.identifier.issn2376-8886
dc.identifier.issn2376-8894
dc.identifier.urihttp://hdl.handle.net/10292/19259
dc.publisherIEEE
dc.relation.urihttps://ieeexplore.ieee.org/document/10780484
dc.rights© 2024 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works
dc.rights.accessrightsOpenAccess
dc.subject46 Information and Computing Sciences
dc.subject40 Engineering
dc.subject3208 Medical Physiology
dc.subject32 Biomedical and Clinical Sciences
dc.subjectelectroencephalography
dc.subjectnon-contact capacitive electrodes
dc.subjectlong term monitoring
dc.subjectear-EEG
dc.titleAdvanced Technique for EEG and HRV Measurement Using Around-Ear Capacitive Electrodes
dc.typeConference Contribution
pubs.elements-id581718

Files

Original bundle

Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
IEEE compatible - Advanced Technique for EEG and HRV Measurement Using Around-ear Capacitive Electrodes.pdf
Size:
643.96 KB
Format:
Adobe Portable Document Format
Description:
Author's accepted manuscript under publisher's embargo until 11th December 2026
Loading...
Thumbnail Image
Name:
Advanced_Technique_for_EEG_and_HRV_Measurement_Using_Around-Ear_Capacitive_Electrodes.pdf
Size:
680.67 KB
Format:
Adobe Portable Document Format
Description:
Evidence for verification