24 GHz Flexible Antenna for Doppler Radar-Based Human Vital Signs Monitoring
| aut.relation.articlenumber | 3737 | |
| aut.relation.issue | 11 | |
| aut.relation.journal | Sensors | |
| aut.relation.startpage | 3737 | |
| aut.relation.volume | 21 | |
| dc.contributor.author | Kathuria, Nitin | |
| dc.contributor.author | Seet, Boon-Chong | |
| dc.date.accessioned | 2026-10-05T19:16:26Z | |
| dc.date.issued | 2021-05-27 | |
| dc.description.abstract | Noncontact monitoring of human vital signs has been an emerging research topic in recent years. A key approach to this monitoring is the use of the Doppler radar concept which enables real-time vital signs detection, resulting in a new class of radar system known as bio-radar. The antennas are a key component of any bio-radar module and their designs should meet the common requirements of bio-radar applications such as high radiation directivity and mechanical flexibility. This paper presents the design of a four-element antenna array on a flexible liquid crystal polymer (LCP) substrate of 100 μm thickness and εr of 3.35. The designed antenna array can be used with a 24 GHz bio-radar for vital signs monitoring in a non-contact manner. It features a relatively compact size of 36.5 × 53 mm2 and measured gain of 5.81 dBi. The two vital signs: breathing rate (BR) and heart rate (HR) of two human subjects are detected with relatively good accuracy using the fabricated antenna array and radio frequency (RF) output power of −3 dBm from a distance of approximately 60 cm. The effect of bending on the antenna performance is also analyzed. | |
| dc.identifier.citation | Sensors, ISSN: 1424-8220 (Print); 1424-8220 (Online), MDPI AG, 21(11), 3737-. doi: 10.3390/s21113737 | |
| dc.identifier.doi | 10.3390/s21113737 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.issn | 1424-8220 | |
| dc.identifier.uri | http://hdl.handle.net/10292/22091 | |
| dc.language | en | |
| dc.publisher | MDPI AG | |
| dc.relation.uri | https://www.mdpi.com/1424-8220/21/11/3737 | |
| dc.rights | © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article. | |
| dc.rights.accessrights | OpenAccess | |
| dc.rights.license | Creative Commons Attribution (CC BY) license | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | Doppler radar | |
| dc.subject | bending analysis | |
| dc.subject | bio-radar | |
| dc.subject | flexible antenna | |
| dc.subject | human vital signs | |
| dc.subject | liquid crystal polymer | |
| dc.subject | noncontact monitoring | |
| dc.subject | Science & Technology | |
| dc.subject | Physical Sciences | |
| dc.subject | Technology | |
| dc.subject | Chemistry, Analytical | |
| dc.subject | Engineering, Electrical & Electronic | |
| dc.subject | Instruments & Instrumentation | |
| dc.subject | Chemistry | |
| dc.subject | Engineering | |
| dc.subject | 40 Engineering | |
| dc.subject | 46 Information and Computing Sciences | |
| dc.subject | 4006 Communications Engineering | |
| dc.subject | 4009 Electronics, Sensors and Digital Hardware | |
| dc.subject | 4605 Data Management and Data Science | |
| dc.subject | 0301 Analytical Chemistry | |
| dc.subject | 0502 Environmental Science and Management | |
| dc.subject | 0805 Distributed Computing | |
| dc.subject | 0906 Electrical and Electronic Engineering | |
| dc.subject | 4008 Electrical engineering | |
| dc.subject | 4104 Environmental management | |
| dc.subject | 4606 Distributed computing and systems software | |
| dc.subject.mesh | Heart Rate | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Radar | |
| dc.subject.mesh | Respiratory Rate | |
| dc.subject.mesh | Ultrasonography, Doppler | |
| dc.subject.mesh | Vital Signs | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Ultrasonography, Doppler | |
| dc.subject.mesh | Heart Rate | |
| dc.subject.mesh | Radar | |
| dc.subject.mesh | Vital Signs | |
| dc.subject.mesh | Respiratory Rate | |
| dc.subject.mesh | Heart Rate | |
| dc.subject.mesh | Humans | |
| dc.subject.mesh | Radar | |
| dc.subject.mesh | Respiratory Rate | |
| dc.subject.mesh | Ultrasonography, Doppler | |
| dc.subject.mesh | Vital Signs | |
| dc.title | 24 GHz Flexible Antenna for Doppler Radar-Based Human Vital Signs Monitoring | |
| dc.type | Journal Article | |
| pubs.elements-id | 430785 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- sensors-21-03737-v2.pdf
- Size:
- 10.11 MB
- Format:
- Adobe Portable Document Format
- Description:
- Journal article