Parametric Electrical Modelling of Human Forearm Simulation Response Using Multi-frequency Electrical Bioimpedance

aut.relation.articlenumber2en_NZ
aut.relation.journalJournal of Biosensors & Bioelectronicsen_NZ
aut.relation.volume7en_NZ
aut.researcherLowe, Andrew
dc.contributor.authorAnand, Gen_NZ
dc.contributor.authorLowe, Aen_NZ
dc.contributor.authorAl-Jumaily, AMen_NZ
dc.date.accessioned2017-07-30T22:18:04Z
dc.date.available2017-07-30T22:18:04Z
dc.date.copyright2016en_NZ
dc.date.issued2016en_NZ
dc.description.abstractThis work presents a parametric electrical modelling of the electrical response of human forearm tissues through a simulation of Multi-frequency Electrical Bioimpedance analysis (MF-EBIA). The objective is to estimate an electrical equivalent representation for tissue response in terms of resistance and capacitance values for three tissue layers in the forearm – the fat, muscle and artery, using parametric fitting analysis. Following up from a simulation study of the human forearm model using Ansys® High Frequency Structure Simulator (HFSS), this work assumes an electrical model of the human forearm section for every tissue and calculates the electrical parameters. The tissue model was considered to be isotropic with regards to the dielectric properties and the consideration of blood flow was realised by taking three instances of radial artery diameter. The proposed model was validated by using the obtained values of model components to reproduce the overall response. The obtained values of resistance and capacitance for every tissue domain provide an insight into their significant contribution to the overall electrical response, which can be important while analysing their individual electrical behaviour and also helpful in various pre-experimental studies related to dielectric characterization of living tissues.
dc.identifier.citationJournal of Biosensors & Bioelectronics, 7: 206. doi:10.4172/2155-6210.1000206
dc.identifier.doi10.4172/2155-6210.1000206en_NZ
dc.identifier.urihttps://hdl.handle.net/10292/10710
dc.publisherOMICS International
dc.relation.urihttps://www.omicsonline.org/open-access/parametric-electrical-modelling-of-human-forearm-simulation-responseusing-multifrequency-electrical-bioimpedance-2155-6210-1000206.php?aid=73495
dc.rights© 2016 Anand G, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
dc.rights.accessrightsOpenAccessen_NZ
dc.subjectBioimpedance; Human forearm; Electrical modelling; Dielectric properties
dc.titleParametric Electrical Modelling of Human Forearm Simulation Response Using Multi-frequency Electrical Bioimpedanceen_NZ
dc.typeJournal Article
pubs.elements-id205555
pubs.organisational-data/AUT
pubs.organisational-data/AUT/Design & Creative Technologies
pubs.organisational-data/AUT/Design & Creative Technologies/Engineering, Computer & Mathematical Sciences
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
parametric-electrical-modelling-of-human-forearm-.pdf
Size:
1.17 MB
Format:
Adobe Portable Document Format
Description:
Journal article
License bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
AUT Grant of Licence for Scholarly Commons Feb2017.pdf
Size:
239.25 KB
Format:
Adobe Portable Document Format
Description: