<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
Repository logo

Design and Statistical Validation of Low-Cost Electrogoniometers for Elbow Orthosis Applications

aut.relation.journalBiomedical Physics and Engineering Express
dc.contributor.authorEscobedo-Magallán, José F
dc.contributor.authorTéllez-Anguiano, Adriana Del Carmen
dc.contributor.authorÁviles-Jr, Manuel
dc.contributor.authorGarcia, Lorenzo
dc.date.accessioned2026-11-08T22:25:55Z
dc.date.issued2026-10-30
dc.description.abstractThis study presents the design, implementation, and statistical validation of four low-cost electromechanical electrogoniometers for elbow joint angle measurement in orthotic applications. The proposed systems are based on distinct sensing principles: an infrared (IR) optical sensor, a calibrated IR optical sensor, a rotary potentiometer, and a slide potentiometer, all integrated into a custom mechanical structure that enables indirect measurement while reducing mechanical stress on sensing components. Experimental validation was performed using a controlled elbow motion simulator and human subjects, with measurements compared against a reference digital goniometer. Performance metrics included mean absolute error (MAE), repeatability, linearity (R²), and statistical agreement. A one-way ANOVA revealed significant differences among sensing modalities (p < 0.05), and Tukey's post hoc analysis confirmed that the IR-based system exhibited significantly higher errors than calibrated IRbased and both potentiometer-based systems. Bland-Altman analysis demonstrated strong agreement for calibrated IR-based and potentiometer-based designs, with minimal bias and narrow limits of agreement. The calibrated IR achieved the highest accuracy (MAE ≈ 2.78°), while the slide potentiometer provided a favorable balance between performance (MAE ≈ 4.72°) and mechanical integration. These results indicate that potentiometer-based electrogoniometers are suitable for wearable rehabilitation systems requiring reliable and realtime joint monitoring. The proposed designs offer cost-effective alternatives for biomechanical instrumentation and support the development of accessible assistive technologies.
dc.identifier.citationBiomedical Physics and Engineering Express, ISSN: 2057-1976 (Print); 2057-1976 (Online), IOP Publishing. doi: 10.1088/2057-1976/aebbc1
dc.identifier.doi10.1088/2057-1976/aebbc1
dc.identifier.issn2057-1976
dc.identifier.issn2057-1976
dc.identifier.urihttp://hdl.handle.net/10292/22342
dc.languageeng
dc.publisherIOP Publishing
dc.relation.urihttps://iopscience.iop.org/article/10.1088/2057-1976/aebbc1
dc.rights© 2026 The Author(s). Published by IOP Publishing Ltd. Open access.
dc.rights.accessrightsOpenAccess
dc.rights.licenseCreative Commons Attribution CC BY 4.0
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectElbow Orthosis
dc.subjectLow-cost electrogoniometers
dc.subjectMedical devices
dc.subjectElbow Orthosis
dc.subjectLow-cost electrogoniometers
dc.subjectMedical devices
dc.subject40 Engineering
dc.subject4009 Electronics, Sensors and Digital Hardware
dc.subjectBioengineering
dc.subjectPhysical Rehabilitation
dc.subjectRehabilitation
dc.subject0903 Biomedical Engineering
dc.subject1004 Medical Biotechnology
dc.subject3206 Medical biotechnology
dc.subject4003 Biomedical engineering
dc.titleDesign and Statistical Validation of Low-Cost Electrogoniometers for Elbow Orthosis Applications
dc.typeJournal Article
pubs.elements-id777132

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Escobedo-Magallán+et+al_2026_Biomed._Phys._Eng._Express.pdf
Size:
1.38 MB
Format:
Adobe Portable Document Format
Description:
Author Accepted Manuscript