<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
⚠️ Scheduled Maintenance: Tuwhera Open Repository When: Wednesday, November 18 | 8:00 AM – 8:15 AM Impact: Service temporarily offline for server migration Please schedule any thesis deposits or resource downloads outside of this window. Thank you for your patience.
Repository logo

Development and Characterization of a Simulink Model and Rule-Based Energy Management for an Off-Grid Hybrid PV–Wind EV Charging Station: A Baseline for Distributionally Robust Control

aut.relation.articlenumber5137
aut.relation.endpage5137
aut.relation.issue21
aut.relation.journalEnergies
aut.relation.startpage5137
aut.relation.volume19
dc.contributor.authorIbezim, Onyeka
dc.contributor.authorPrasad, Krishnamachar
dc.contributor.authorKilby, Jeff
dc.date.accessioned2026-11-16T02:15:02Z
dc.date.issued2026-10-28
dc.description.abstractThis study presents a developed and characterized Simulink model of an off-grid hybrid photovoltaic (PV) and wind electric vehicle (EV) charging station and characterizes the performance of a rule-based energy management strategy (EMS) that coordinates its four power branches. Predominantly techno-economic studies of such architectures have not provided dynamic models sufficiently to characterize transient behavior, mode transitions, or control limitations. The model integrates a 78.1 kW PV array, a 20 kW wind turbine, a 150 kWh energy-storage unit, and a 25 kW EV port on a regulated 600 V DC bus. Each subsystem is characterized in isolation; the integrated system is exercised under a 50 s four-window stepped-irradiance scenario. During high- and low-irradiance windows, the EMS coordinates all four branches successfully, with bus voltage regulated within ±7 V of a +3.7% steady-state offset. At the intermediate-irradiance window, the filtered PV power oscillates across the hysteresis band, producing 74 charge/discharge transitions in 10 s and sub-millisecond bus voltage transients reaching 903 V, exceeding the 750 V safety threshold. Remediation experiments show that a 50 ms debounce eliminates the chatter but not the transient, identifying two independent architectural limitations of the rule-based design. The dynamic model and baseline established here inform a companion two-stage distributionally robust optimization (TSDRO) controller for the same architecture.
dc.identifier.citationEnergies, ISSN: 1996-1073 (Print); 1996-1073 (Online), MDPI AG, 19(21), 5137-5137. doi: 10.3390/en19215137
dc.identifier.doi10.3390/en19215137
dc.identifier.issn1996-1073
dc.identifier.issn1996-1073
dc.identifier.urihttp://hdl.handle.net/10292/22400
dc.languageen
dc.publisherMDPI AG
dc.relation.urihttps://www.mdpi.com/1996-1073/19/21/5137
dc.rights© 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article.
dc.rights.accessrightsOpenAccess
dc.rights.licenseCreative Commons Attribution (CC BY) license
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subject40 Engineering
dc.subject4008 Electrical Engineering
dc.subject4009 Electronics, Sensors and Digital Hardware
dc.subject7 Affordable and Clean Energy
dc.subject02 Physical Sciences
dc.subject09 Engineering
dc.subject33 Built environment and design
dc.subject51 Physical sciences
dc.subjectoff-grid charging
dc.subjecthybrid PV–wind
dc.subjectEV charging
dc.subjectSimulink modeling
dc.subjectenergy management system
dc.subjectrule-based control
dc.subjectdistributionally robust optimization
dc.titleDevelopment and Characterization of a Simulink Model and Rule-Based Energy Management for an Off-Grid Hybrid PV–Wind EV Charging Station: A Baseline for Distributionally Robust Control
dc.typeJournal Article
pubs.elements-id777170