Development and Characterization of a Simulink Model and Rule-Based Energy Management for an Off-Grid Hybrid PV–Wind EV Charging Station: A Baseline for Distributionally Robust Control
| aut.relation.articlenumber | 5137 | |
| aut.relation.endpage | 5137 | |
| aut.relation.issue | 21 | |
| aut.relation.journal | Energies | |
| aut.relation.startpage | 5137 | |
| aut.relation.volume | 19 | |
| dc.contributor.author | Ibezim, Onyeka | |
| dc.contributor.author | Prasad, Krishnamachar | |
| dc.contributor.author | Kilby, Jeff | |
| dc.date.accessioned | 2026-11-16T02:15:02Z | |
| dc.date.issued | 2026-10-28 | |
| dc.description.abstract | This study presents a developed and characterized Simulink model of an off-grid hybrid photovoltaic (PV) and wind electric vehicle (EV) charging station and characterizes the performance of a rule-based energy management strategy (EMS) that coordinates its four power branches. Predominantly techno-economic studies of such architectures have not provided dynamic models sufficiently to characterize transient behavior, mode transitions, or control limitations. The model integrates a 78.1 kW PV array, a 20 kW wind turbine, a 150 kWh energy-storage unit, and a 25 kW EV port on a regulated 600 V DC bus. Each subsystem is characterized in isolation; the integrated system is exercised under a 50 s four-window stepped-irradiance scenario. During high- and low-irradiance windows, the EMS coordinates all four branches successfully, with bus voltage regulated within ±7 V of a +3.7% steady-state offset. At the intermediate-irradiance window, the filtered PV power oscillates across the hysteresis band, producing 74 charge/discharge transitions in 10 s and sub-millisecond bus voltage transients reaching 903 V, exceeding the 750 V safety threshold. Remediation experiments show that a 50 ms debounce eliminates the chatter but not the transient, identifying two independent architectural limitations of the rule-based design. The dynamic model and baseline established here inform a companion two-stage distributionally robust optimization (TSDRO) controller for the same architecture. | |
| dc.identifier.citation | Energies, ISSN: 1996-1073 (Print); 1996-1073 (Online), MDPI AG, 19(21), 5137-5137. doi: 10.3390/en19215137 | |
| dc.identifier.doi | 10.3390/en19215137 | |
| dc.identifier.issn | 1996-1073 | |
| dc.identifier.issn | 1996-1073 | |
| dc.identifier.uri | http://hdl.handle.net/10292/22400 | |
| dc.language | en | |
| dc.publisher | MDPI AG | |
| dc.relation.uri | https://www.mdpi.com/1996-1073/19/21/5137 | |
| dc.rights | © 2026 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article. | |
| dc.rights.accessrights | OpenAccess | |
| dc.rights.license | Creative Commons Attribution (CC BY) license | |
| dc.rights.uri | https://creativecommons.org/licenses/by/4.0/ | |
| dc.subject | 40 Engineering | |
| dc.subject | 4008 Electrical Engineering | |
| dc.subject | 4009 Electronics, Sensors and Digital Hardware | |
| dc.subject | 7 Affordable and Clean Energy | |
| dc.subject | 02 Physical Sciences | |
| dc.subject | 09 Engineering | |
| dc.subject | 33 Built environment and design | |
| dc.subject | 51 Physical sciences | |
| dc.subject | off-grid charging | |
| dc.subject | hybrid PV–wind | |
| dc.subject | EV charging | |
| dc.subject | Simulink modeling | |
| dc.subject | energy management system | |
| dc.subject | rule-based control | |
| dc.subject | distributionally robust optimization | |
| dc.title | Development and Characterization of a Simulink Model and Rule-Based Energy Management for an Off-Grid Hybrid PV–Wind EV Charging Station: A Baseline for Distributionally Robust Control | |
| dc.type | Journal Article | |
| pubs.elements-id | 777170 |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Ibezim et al_2026_Development and characterization of a Simulink model.pdf
- Size:
- 2.71 MB
- Format:
- Adobe Portable Document Format
- Description:
- Journal article