<link rel="stylesheet" href="styles.cf390c6bfbe7555f.css">
Repository logo

Control Strategies and Stabilisation Techniques for DC/DC Converter

Loading...
Thumbnail Image

Files

Size: 35.74 MB, File format: Adobe PDF

Date

Authors

Nduwamungu, Aphrodis

Supervisor

Lie, Tek Tjing

Gunawardane, Kosala

Nair, Nirmal N K

Lestas, Ionnis

Item type

Journal Title

Journal ISSN

Volume Title

Publisher

Auckland University of Technology

Abstract

This research investigates control strategies and stabilisation techniques for dual active bridge (DAB) and quad active bridge (QAB) converters in low-voltage DC (LVDC) microgrids supplying resistive loads, constant-power loads (CPLs) and pulsed-power loads (PPLs). These loads, the coupling between the ports of multiport converters and the nonlinear converter dynamics make fast and stable voltage regulation difficult. The thesis makes six contributions. First, a generalised harmonic model of the four-winding QAB transformer currents, including the dead time, agrees with a detailed switching simulation within 5.2% up to the 15th harmonic and supplies the coefficients of the control model; even harmonics appear only when the two half-cycles are unequal. Second, an adaptive super-twisting sliding mode controller (ASTSMC) with a nonlinear extended state observer and a feedforward decoupler is proposed for the QAB with CPLs, with a Lyapunov proof of practical finite-time stability and bounded adaptive gains. It settled a 48→60 V reference step in 1.14 ms, against 1.50 ms for an SMC with a nonlinear extended state observer and 6.00 ms for a decoupled PID, and gave the smallest dip after a load step (2.33%). Third, three known nonlinear controllers were customised for the QAB with PPLs; for a 100→200 W PPL step, the adaptive suboptimal second-order SMC limited the voltage change to 0.5/0.3 V, against up to 4.2 V for the others, at almost the same efficiency (90.72% against 90.78%). Fourth, for a resonant DAB with CPLs, a variable-gain SMC was derived that remains stable even when its base gain is below the worst disturbance, and it was combined with a physics-informed neural network (PINN) that estimates the unknown disturbance current. The PINN estimate was correct on new runs (R2 = 0.991), and after a 300→900 W CPL step the voltage drop fell from 6.2% without an estimator to 3.7%, close to an SMC with a linear extended state observer (3.1%) and better than a twisting second-order SMC. Fifth, a common test method applies the same tests, limits and tuning to all controllers of a chapter. Sixth, a laboratory DAB prototype with an OPAL-RT interface was built and tested in open loop. The controllers were evaluated in MATLAB/Simulink simulation and run on an OPAL-RT OP5700 simulator (software-in-the-loop); closed-loop tests on hardware remain future work.

Description

Keywords

Source

DOI

Publisher's version

Rights statement

Collections

Endorsement

Review

Supplemented By

Referenced By