AUT LibraryAUT
View Item 
  •   Open Research
  • AUT Faculties
  • Faculty of Health and Environmental Sciences
  • School of Clinical Sciences
  • View Item
  •   Open Research
  • AUT Faculties
  • Faculty of Health and Environmental Sciences
  • School of Clinical Sciences
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Reliability of Tibialis Anterior Muscle Voluntary Activation Using the Interpolated Twitch Technique and the Central Activation Ratio in People With Stroke

Olsen, S; Signal, N; Niazi, IK; Alder, G; Rashid, U; Nedergaard, RB; Taylor, D
Thumbnail
View/Open
Journal article (1.697Mb)
Permanent link
http://hdl.handle.net/10292/14045
Metadata
Show full metadata
Abstract
Voluntary activation (VA) is measured by applying supramaximal electrical stimulation to a muscle during a maximal voluntary contraction (MVC). The amplitude of the evoked muscle twitch is used to determine any VA deficit, and indicates incomplete central neural drive to the motor units. People with stroke experience VA deficits and greater levels of central fatigue, which is the decrease in VA that occurs following exercise. This study investigated the between-session reliability of VA and central fatigue of the tibialis anterior muscle (TA) in people with chronic stroke (n = 12), using the interpolated twitch technique (ITT), adjusted-ITT, and central activation ratio (CAR) methods. On two separate sessions, supramaximal electrical stimulation was applied to the TA when it was at rest and maximally activated, at the start and end of a 30-s isometric dorsiflexor MVC. The most reliable measures of VA were obtained using the CAR calculation on transformed data, which produced an ICC of 0.92, and a lower bound confidence interval in the good range (95% CI 0.77 to 0.98). Reliability was lower for the CAR calculation on non-transformed data (ICC 0.82, 95% CI 0.63 to 0.91) and the ITT and adjusted-ITT calculations on transformed data (ICCs 0.82, 95% CIs 0.51 to 0.94), which had lower bound confidence intervals in the moderate range. The two ITT calculations on non-transformed data demonstrated the poorest reliability (ICCs 0.62, 95% CI 0.25 to 0.74). Central fatigue measures demonstrated very poor reliability. Thus, the reliability for VA in people with chronic stroke ranged from good to poor, depending on the calculation method and statistical analysis method, whereas the reliability for central fatigue was very poor.
Keywords
Central activation ratio; Interpolated twitch; Reliability; Stroke; Voluntary activation
Date
2021
Source
Brain Sciences, 11(2), 176. doi:10.3390/brainsci11020176
Item Type
Journal Article
Publisher
MDPI AG
DOI
10.3390/brainsci11020176
Publisher's Version
https://www.mdpi.com/2076-3425/11/2/176
Rights Statement
© 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).

Contact Us
  • Admin

Hosted by Tuwhera, an initiative of the Auckland University of Technology Library

 

 

Browse

Open ResearchTitlesAuthorsDateSchool of Clinical SciencesTitlesAuthorsDate

Alternative metrics

 

Statistics

For this itemFor all Open Research

Share

 
Follow @AUT_SC

Contact Us
  • Admin

Hosted by Tuwhera, an initiative of the Auckland University of Technology Library