Incidence in Plasma of Low Level Antibodies Against Three Xenotransplantation and Immunotherapeutic Glycan Antigens

Date
2020
Authors
Perry, H
Ryzhov, I
Galanina, O
V Bovin, N
M Henry, S
Supervisor
Item type
Journal Article
Degree name
Journal Title
Journal ISSN
Volume Title
Publisher
American Institute of Mathematical Sciences (AIMS)
Abstract

Antibodies against xeno-glycan antigens terminating with the saccharides Galα, GalNAcα and Rhaα are ubiquitous in human blood. Although originating as barriers to infection some of these naturally occurring complement-activating antibodies also contribute to disease processes, hinder xenotransplantation and have potential medical roles in immuno-oncotherapy. Because concentration of antibody is important in determining biological activity, there is a need to understand population variation in naturally occurring antibody levels, and to be able to rapidly and accurately determine levels in individuals. Xeno-glycan antigens in the form of function-spacer-lipid constructs were used to modify human red cells (kodecytes) to have on their surface micromolar equivalents of the xeno-glycan antigens Galα1-3Galβ1-4GlcNAc, GalNAcα1-3Galβ1-4GlcNAc and Rhaα. The methodology used was based on a previously validated kodecyte method used for quantifying IgM and IgG ABO human blood group antibodies in undiluted plasma. We tested plasma samples from 100 healthy individuals against these three different xeno-glycan kodecytes with each at three different loading concentrations of antigen to determine relative levels of these antibodies in human plasma. Sixty-one samples were also independently tested by enzyme immunoassay to correlate levels of anti-Galα. Results demonstrate independence between antibody specificities and substantial variation between individuals in levels of these antibodies, with >92% of the population having medium or high levels of at least one specificity. However, of particular importance was that 5–8% of the population had low levels of both IgM and IgG to at least one specificity and these individuals would probably have a poor immediate response when challenged by the corresponding antigen.

Description
Keywords
Xeno-glycan antigens; Function-spacer-lipid constructs; Kodecytes
Source
AIMS Allergy and Immunology, 2020, 4(4): 75-87. doi: 10.3934/Allergy.2020007
Rights statement
© 2020 the Author(s), licensee AIMS Press. This is an open access article distributed under the terms of the Creative Commons Attribution Licese (http://creativecommons.org/licenses/by/4.0)