Show simple item record

dc.date.accessioned2018-05-10T22:41:21Z
dc.date.available2018-05-10T22:41:21Z
dc.date.copyright2009en_NZ
dc.identifier.citationJournal of Foot and Ankle Research, 2009, 2:33, https://doi.org/10.1186/1757-1146-2-33
dc.identifier.issn1757-1146en_NZ
dc.identifier.urihttp://hdl.handle.net/10292/11548
dc.description.abstractBackground Diagnostic ultrasound provides a method of analysing soft tissue structures of the musculoskeletal system effectively and reliably. The aim of this study was to evaluate within and between session reliability of measuring muscle dorso-plantar thickness, medio-lateral length and cross-sectional area, of the abductor hallucis muscle using two different ultrasound machines, a higher end Philips HD11 Ultrasound machine and clinically orientated Chison 8300 Deluxe Digital Portable Ultrasound System. Methods The abductor hallucis muscle of both the left and right feet of thirty asymptomatic participants was imaged and then measured using both ultrasound machines. Interclass correlation coefficients (ICC) with 95% confidence intervals (CI) were used to calculate both within and between session intra-tester reliability. Standard error of the measurement (SEM) calculations were undertaken to assess difference between the actual measured score across trials and the smallest real difference (SRD) was calculated from the SEM to indicate the degree of change that would exceed the expected trial to trial variability. Results The ICCs, SEM and SRD for dorso-plantar thickness and medial-lateral length were shown to have excellent to high within and between-session reliability for both ultrasound machines. The between-session reliability indices for cross-sectional area were acceptable for both ultrasound machines. Conclusion The results of the current study suggest that regardless of the type ultrasound machine, intra-tester reliability for the measurement the abductor hallucis muscle parameters is very high.en_NZ
dc.languageengen_NZ
dc.publisherBioMed Central
dc.relation.urihttps://jfootankleres.biomedcentral.com/articles/10.1186/1757-1146-2-33
dc.rightsThis article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
dc.subjectHallux Valgus; Abductor Hallucis; Muscle Parameter; Interclass Correlation Coefficient; Abductor Hallucis Muscle
dc.titleReliability of measuring abductor hallucis muscle parameters using two different diagnostic ultrasound machinesen_NZ
dc.typeJournal Article
dc.rights.accessrightsOpenAccessen_NZ
dc.identifier.doi10.1186/1757-1146-2-33en_NZ
dark.contributor.authorHing, WAen_NZ
dark.contributor.authorRome, Ken_NZ
dark.contributor.authorCameron, AFen_NZ
aut.relation.startpage33
aut.relation.volume2en_NZ
pubs.elements-id36339
aut.relation.journalJournal of Foot and Ankle Researchen_NZ


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record