Investigation of seal performance in a 4-α double-acting Stirling cycle heat-pump/refrigerator
aut.conference.type | Paper Published in Proceedings | |
aut.researcher | Gschwendtner, Michael | |
dc.contributor.author | Haywood, D | |
dc.contributor.author | Raine, JK | |
dc.contributor.author | Gschwendtner, MA | |
dc.date.accessioned | 2012-12-18T01:57:24Z | |
dc.date.available | 2012-12-18T01:57:24Z | |
dc.date.copyright | 2001 | |
dc.date.issued | 2001 | |
dc.description.abstract | Concerns about the environmental impact of refrigerants used in vapour-compression heatpumps and refrigerators, have prompted the Stirling-Cycle Research Group at the University of Canterbury to investigate the feasibility of low-cost Stirling-cycle machines that use air as the refrigerant. Seal development is a key part of the research programme, and a series of experiments has been carried out in order to ascertain the suitability of a system using low-cost rubbing seals. Investigations have been based on a Stirling-cycle heat-pump using a wobble-yoke kinematic mechanism in a 4-α double-acting (Siemens) configuration. An automotive-type piston arrangement was employed, using Low Wear Rate Polymer (LWRP) seal-rings. The experiments highlighted some of the weaknesses of the 4-α double-acting configuration in terms of seal behaviour. While reasonable performance was attained, the difficulty of achieving adequate sealing during pressure reversal across the piston means that other configurations may be more suitable for Stirling-cycle heat-pump/refrigerator machines. | |
dc.identifier.citation | 10th International Stirling Engine Conference, Osnabrück, Germany, 2001 to 2001, published in: International Stirling Engine Conference Proceedings | |
dc.identifier.uri | https://hdl.handle.net/10292/4941 | |
dc.publisher | International Stirling Engine, Universita de Roma | |
dc.rights | Auckland University of Technology (AUT) encourages public access to AUT information and supports the legal use of copyright material in accordance with the Copyright Act 1994 (the Act) and the Privacy Act 1993. Unless otherwise stated, copyright material contained on this site may be in the intellectual property of AUT, a member of staff or third parties. Any commercial exploitation of this material is expressly prohibited without the written permission of the owner. | |
dc.rights.accessrights | OpenAccess | |
dc.title | Investigation of seal performance in a 4-α double-acting Stirling cycle heat-pump/refrigerator | |
dc.type | Conference Contribution | |
pubs.elements-id | 132154 | |
pubs.organisational-data | /AUT | |
pubs.organisational-data | /AUT/Design & Creative Technologies | |